DBT Series Low-Voltage Frequency Converter
DBT is a general-purpose vector VFD for speed, torque and process control. It supports induction, permanent magnet synchronous and synchronous reluctance motors, with V/F, sensorless and closed-loop vector control.
Typical Applications
IApplications: Industrial drives, automation and energy-efficiency upgrades.
Equipment: Fans, pumps, compressors and material-handling equipment.
Product Overview
Typical Challenges

Product Features

Specifications

| Basic Functions | Overvoltage/Overcurrent Stall Prevention | Automatically limits current and voltage during operation to prevent overcurrent or overvoltage trips. |
|---|---|---|
| Torque Limiting and Control | Torque control is available in vector control mode. Torque is automatically limited during operation to prevent overcurrent trips. | |
| Communication | RS485 Bus | Modbus RTU, Modbus ASCII |
| Operation | Run Command | Keypad, control terminals or serial communication; selectable by multiple methods. |
| Frequency Reference | 10 frequency reference options, including digital setting, analog voltage, analog current, pulse and serial communication; selectable by multiple methods. | |
| Auxiliary Frequency Reference | 5 auxiliary frequency reference options for flexible frequency fine-tuning and combined frequency references. | |
| Input Terminals | Standard: 7 DI terminals, with X7 supporting high-speed pulse input up to 10 kHz; 2 AI terminals supporting 0–10 V input, with AI2 also supporting 0–20 mA input. | |
| Output Terminals | Standard: 1 open-collector output, 1 relay output and 2 AO terminals supporting 0–10 V output, with AO2 also supporting 0–20 mA output. | |
| Display and Keypad | LED Display | Parameter display |
| Key Lock and Function Selection | Partial or full keypad locking, with configurable functions for selected keys to prevent incorrect operation. | |
| Protection Functions | Phase-Loss Protection | Output phase-loss protection |
| Overcurrent Protection | Trips when the current exceeds 2.0 times the rated VFD current. | |
| Overvoltage Protection | Trips when the main-circuit DC voltage is too high. | |
| Undervoltage Protection | Trips when the main-circuit DC voltage is too low. | |
| Overtemperature Protection | Protection is triggered when the rectifier or inverter module overheats. | |
| Overload Protection | Trips after 60 s at 150% of rated current. | |
| Environment | Installation Location | Indoors, away from direct sunlight; free from dust, corrosive gases, flammable gases, oil mist, water vapor, dripping water and salt. |
| Altitude | Below 1,000 m; derate by 1% for every additional 100 m above 1,000 m. | |
| Ambient Temperature | −10°C to +40°C; derating is required above 40°C. | |
| Humidity | <90% RH, non-condensing | |
| Vibration | <4.9 m/s² (0.5 g) |
Data Download

| Name |
Version |
format |
Size |
Date |
Download |
| DBT-Low-voltage Variable Frequency Drive | V1.0 | 1.5MB | 2026-11-11 |
Related Products